Accedi

Performing 1D Thin Layer Chromatography

Panoramica

Source: Laboratory of Dr. Yuri Bolshan — University of Ontario Institute of Technology

Thin layer chromatography (TLC) is a chromatographic method used to separate mixtures of non-volatile compounds. A TLC plate consists of a thin layer of adsorbent material (the stationary phase) fixed to an appropriate solid support such as plastic, aluminum, or glass1. The sample(s) and reference compound(s) are dissolved in an appropriate solvent and applied near the bottom edge of the TLC plate in small spots. The TLC plate is developed by immersing the bottom edge in the developing solvent consisting of an appropriate mobile phase. Capillary action allows the mobile phase to move up the adsorbent layer. As the solvent moves up the TLC plate, it carries with it the components of each spot and separates them based on their physical interactions with the mobile and stationary phases.

Principi

Chromatography involves the separation of a mixture of compounds by distributing the components between two phases2. The stationary phase is fixed in place while the mobile phase is allowed to flow through the stationary phase, carrying the components of the mixture with it. The properties of compounds such as solubility in the mobile phase and the strength of interaction with the stationary phase affect the rate at which they are carried through the medium. Since different types of compounds have different physical properties, they are carried at different rates allowing for separation of the components of a mixture.

This video will demonstrate the separation and visualization of mixtures of compounds using the technique of one-dimensional thin layer chromatography (TLC).

Procedura

1. TLC Plates

  1. Common adsorbents for TLC are silica gel, alumina, and cellulose. TLC plates are commercially available with a variety of properties. Choose a TLC plate and cut it down to an appropriate size (approximately 5 cm x 5 cm is sufficient for most applications). For glass-backed TLC plates, score the glass using a ruler and a glass cutter, then carefully break along the line.

2. Spotting

  1. Dissolve the sample in a suitable solvent to make an approximately 1% solution. If possible the solvent should be nonpolar. Column chromatography fractions and other dilute solutions may be used without dilution if the solute is present at a concentration between 0.2% and 2.0%.
  2. Mark the baseline with a pencil about 1.0 cm from the bottom of the plate. Position the spots at least 1.0 cm from the edge of the plate and label them appropriately.
  3. Spots may be applied using a glass capillary. To spot the TLC plate, dip the capillary into the solution to draw in a small quantity of liquid. Gently touch the tip to the desired location on the TLC plate and remove it immediately.
  4. Alternatively, apply spots with a microliter syringe by delivering approximately 1 μL of solution for each application.
  5. Spots may be applied successively at each location, taking care not to disturb the surface of the adsorbent with the spotter. Allow solvent to dry in between applications.

3. Choosing a Developing Solvent

  1. It is preferable to use the least polar solvent possible for good separation. Common solvents for TLC include hexane, ethyl acetate, dichloromethane, and methanol (Table 1).
  2. A convenient way to find an appropriate mobile phase is to spot the TLC plate with a sample. Apply enough solvent directly to the spot to form a circle of solvent 1–2 cm in diameter. Mark the circumference of the circle. Upon visualization an appropriate solvent will show well-separated rings, with the outermost ring about 50% of the distance from the center to the solvent front.
  3. It may be necessary to adjust the polarity of the mobile phase by choosing two miscible solvents and testing them in varying proportions. Examples of common mixtures are hexanes with ethyl acetate and dichloromethane with methanol.

4. Development

  1. Place the spotted TLC plate in a developing chamber containing the appropriate developing solvent. The solvent line should be below the baseline marked on the TLC plate.
  2. The developing chamber can be a jar with a lid, or a beaker covered with aluminum foil or plastic film. Use the smallest container available that will accommodate the TLC plate.
  3. Do not allow the solvent to reach the top edge of the plate. When the solvent front (the boundary where the wet part of the adsorbent ends) is 5–10 mm from the top the plate, remove the TLC plate from the developing chamber and mark the solvent front with a pencil before the solvent dries.

5. Visualization

  1. Colored spots may be visualized immediately and marked with a pencil. Often, spots are not visible and therefore must be visualized by some other method.
  2. Often, the TLC adsorbent contains a fluorescent indicator. Spots may be visualized using a hand-held ultraviolet (UV) lamp. Compounds that quench fluorescence will appear as dark spots when the plate is irradiated with short-wave (254 nm) UV light. Fluorescent compounds will produce bright spots when irradiated with UV light of an appropriate wavelength. Mark the center of each spot with a pencil.
  3. Spots may also be visualized by applying a visualizing reagent or stain to the TLC plate. The visualizing reagent may be applied by dipping the plate into the reagent, or by wiping the plate with a cotton ball saturated with a noncorrosive reagent.
  4. A 20% solution of phosphomolybdic acid in ethanol is useful for the visualization of most organic compounds. The spots appear upon heating of the plate with a heat gun or in an oven.
  5. Other reagents may be used for visualization of specific classes of compounds. For example, ninhydrin reagent is used for amino acid visualization, and 2,4-dinitrophenylhydrazine for aldehydes and ketones.

6. Analysis

  1. The retardation factor (Rf) is the ratio of the distance a compound travels up a TLC plate to the distance the solvent travels. This may be determined by measuring the distance from the baseline to the center of the spot and dividing the value by the distance from the baseline to the solvent front.
  2. The Rf of a compound is characteristic of its physical properties and dependent on factors such as temperature, sample size, and thickness and activity of the adsorbent, temperature, and sample size.
  3. To confirm that an unknown is identical to a known compound, a standard should be spotted on the same TLC plate. Identical substances will have the same characteristic Rf.

Risultati

An example of a typical TLC plate is shown in Figure 1. An unknown compound 'A' may be compared to known standards 'B' through 'E'. Determination of the Rf value for each component is achieved by spotting of each respective compound, developing the TLC plate, and visualization. The Rf of unknown compound 'A' is calculated by measuring the spot height (y) and dividing by the solvent height (z). Comparing this value to the Rf determined for each of the standards allows for the identification of the unknown compound.


Figure 1. Schematic of a TLC plate. The retardation factor (Rf) should be consistent between experiments as long as the conditions are held constant.


Table 1. Eluotropic Series for Silica Gel. A list of common mobile phases in order of increasing eluting power.

Riferimenti

  1. Lehman, J. W. The student's lab companion: laboratory techniques for organic chemistry: standard scale and microscale. Pearson College Div, (2008).
  2. Pavia, D. L., Lampman, G. M., Kriz, G. S., & Engel, R. G. Microscale and Macroscale Techniques. Thomson Wadsworth, (2006).
  3. Pannkuk, E. L., Risch, T. S., Savary, B. J. Profiling the Triacylglyceride Contents in Bat Integumentary Lipids by Preparative Thin Layer Chromatography and MALDI-TOF Mass Spectrometry. J. Vis. Exp. (79), e50757, (2013).
  4. Kagan, I. A., Flythe, M. D. Thin-layer Chromatographic (TLC) Separations and Bioassays of Plant Extracts to Identify Antimicrobial Compounds. J. Vis. Exp. (85), e51411, (2014).

Divulgazioni

No conflicts of interest declared.

Tags

Thin Layer ChromatographyTLCChromatographic MethodNon volatile CompoundsGlass backed PlatePlastic backed PlateBaselineLabelsSolventMobile PhaseResolving PowerQualitative AnalysisPreparationOperationAnalysisStationary PhaseMobile PhasePolar SubstanceSilica GelNon polar LiquidCapillary ActionPolarity

Vai a...

0:00

Overview

1:08

Principles of Thin Layer Chromatography

2:08

Choosing a Mobile Phase

3:30

Spotting the TLC Plate

4:51

Development and Visualization

6:34

Analysis

7:41

Applications

9:22

Summary

Video da questa raccolta:

article

Now Playing

Performing 1D Thin Layer Chromatography

Organic Chemistry

288.4K Visualizzazioni

article

Introduzione alla catalisi

Organic Chemistry

34.1K Visualizzazioni

article

Assemblaggio di un sistema a riflusso per reazioni chimiche riscaldate

Organic Chemistry

166.3K Visualizzazioni

article

Esecuzione di reazioni al di sotto della temperatura ambiente

Organic Chemistry

70.3K Visualizzazioni

article

Trasferimento di solventi tramite linea Schlenk

Organic Chemistry

41.5K Visualizzazioni

article

Degasaggio di liquidi con ciclo freeze-pump-thaw

Organic Chemistry

55.9K Visualizzazioni

article

Preparazione di reagenti anidri e relativa strumentazione

Organic Chemistry

79.1K Visualizzazioni

article

Purificazione di composti tramite ricristallizzazione

Organic Chemistry

705.5K Visualizzazioni

article

Separazione di miscele tramite precipitazione

Organic Chemistry

157.2K Visualizzazioni

article

Estrazione solido-liquido (lisciviazione)

Organic Chemistry

237.2K Visualizzazioni

article

Rimozione dei solventi con evaporatore rotante

Organic Chemistry

212.4K Visualizzazioni

article

Distillazione frazionata

Organic Chemistry

332.9K Visualizzazioni

article

Preparazione di cristalli per l'analisi mediante diffrazione dei raggi X

Organic Chemistry

32.3K Visualizzazioni

article

Cromatografia su colonna

Organic Chemistry

358.5K Visualizzazioni

article

Spettroscopia a risonanza magnetica nucleare (NMR)

Organic Chemistry

246.8K Visualizzazioni

JoVE Logo

Riservatezza

Condizioni di utilizzo

Politiche

Ricerca

Didattica

CHI SIAMO

Copyright © 2025 MyJoVE Corporation. Tutti i diritti riservati