Source: Laboratories of Dr. Ian Pepper and Dr. Charles Gerba -The University of Arizona
Demonstrating Author: Luisa Ikner
Water quality analysis monitors anthropogenic influences such as pollutants, nutrients, pathogens, and any other constituent that can impact the water’s integrity as a resource. Fecal contamination contributes microbial pathogens that threaten plant, animal, and human health with disease or illness. Increasing water demands and strict quality standards require that water being supplied for human or environmental resources be monitored for low pathogen levels. However, monitoring each pathogen associated with fecal pollution is not feasible, as laboratory techniques involve extensive labor, time, and costs. Therefore, detection for indicator organisms provides a simple, rapid, and cost effective technique to monitor pathogens associated with unsanitary conditions.
Indicators are easily detectable organisms whose presence correlates directly to one or more pathogens contaminating an environment. In order to be considered an appropriate indicator, an organism must meet the five following criterion:
Most indicators are enteric organisms or viruses, which are commonly found in warm blooded mammalian and avian gastrointestinal systems, giving a direct connection to fecal contamination. However, many indicators can lack effectiveness due to a poor correlation with certain pathogens. Two of the most widely accepted bacterial indicator organisms are Escherichia coli and coliforms due to their fecal linkages, and ease in laboratory analysis.
Colilert is a defined substrate technology (DST) approach for simultaneous detection, specific identification, and confirmation for E. coli and total coliforms in water samples. This laboratory technique utilizes substrate nutrients specific to each indicator organisms’ metabolic pathway, enumerating only desired microorganisms, which release a signal when the bacteria alter the compound. In the presence of a coliform, the ortho-nitrophenyl-β-D-galactopyranoside (ONPG) nutrient is hydrolyzed by the coliform’s β-galactosidase enzyme. The product compound, ortho-nitrophenyl, is a chromogen that releases a color signal, turning the water yellow (Figure 1).
Figure 1. Schematic showing ortho-nitrophenyl releasing a color signal, turning the water yellow.
In the presence of E. coli, the methylumbelliferyl-β-D-glucuronide (MUG) nutrient is cleaved by the bacteria’s glucuronidase enzyme, producing a methylumbelliferone product that fluoresces blue-green under ultraviolet light (Figure 2).
Figure 2. Schematic showing the methylumbelliferyl-β-D-glucuronide (MUG) nutrient cleaved by the bacteria’s glucuronidase enzyme, producing a methylumberlliferone product that fluoresces blue-green under ultraviolet light.
Colilert can be performed as a presence-absence (P-A) test to indicate whether or not the organisms exist in the sample. This test is completed by dissolving the substrate into 100 mL water samples, incubating at 35 ± 0.5 °C for 24 h, and observing the color signals. The indicators’ presence can also be quantified by utilizing a system which determines the most probable number (MPN) for each organism. This procedure involves dissolving the substrate into 100 mL water samples that are sealed into a tray containing 49 large wells and 48 small wells. The tray is incubated at 35 ± 0.5 °C for 24 h, and then the wells containing positive color changes are counted. The ratio of large to small wells containing positive signals is aligned to the MPN chart that provides the quantification for the presence of each indicator organism present. Regulations for drinking water in the United States require that zero coliforms be present in 100 mL of drinking water.
1. Colilert Presence – Absence (P – A) Test
Figure 3. P-A test negative (left), coliform positive (middle), and E. coli positive (right).
2. Colilert MPN: Quanti-tray 2000
Figure 4. Quanti-tray negative (left), coliform positive (middle), and E. coli positive (right).
Indicator organisms are employed to rapidly and inexpensively determine environmental contamination. Colilert assays are utilized to analyze water quality for drinking, recreational, and wastewater sources. Water quality must meet legal standards set by the Environmental Protection Agency (EPA) and state regulatory departments in order to be accepted as a resource for human and/or environmental consumption.
Colilert assays are also strategically used as mass balance markers within environmental research, and this data can be analyzed along with other environmental assays to measure the correlation between results. Performing a simple P-A Colilert test gives indication whether a sample is contaminated, which can be analyzed alongside research results. If the P-A sample shows that there is contamination in the water, then the water samples being utilized in research may also have contamination that leads to misinterpreted results, while the MPN Quanti-tray provides a baseline quantification for contamination present. For example, the indicator organisms can be used to correlate indicator quantifications with the number of pathogens found in a water sample. If the quanti-tray enumerates low indicator numbers, this suggests that the water sample should also experience similar trends with low pathogen levels.
Przejdź do...
Filmy z tej kolekcji:
Now Playing
Environmental Microbiology
29.5K Wyświetleń
Environmental Microbiology
359.5K Wyświetleń
Environmental Microbiology
126.4K Wyświetleń
Environmental Microbiology
100.3K Wyświetleń
Environmental Microbiology
42.3K Wyświetleń
Environmental Microbiology
57.3K Wyświetleń
Environmental Microbiology
28.8K Wyświetleń
Environmental Microbiology
44.6K Wyświetleń
Environmental Microbiology
40.4K Wyświetleń
Environmental Microbiology
47.8K Wyświetleń
Environmental Microbiology
39.3K Wyświetleń
Environmental Microbiology
40.7K Wyświetleń
Environmental Microbiology
184.5K Wyświetleń
Environmental Microbiology
296.0K Wyświetleń
Environmental Microbiology
13.8K Wyświetleń
Copyright © 2025 MyJoVE Corporation. Wszelkie prawa zastrzeżone